This page summarizes Xingda's transformer bushings manufactured to the EN (British/European) standard system — 10 standard models in three groups, covering 1~36kV and 250~3150A. All are porcelain construction, supplied complete with tank-cover openings (Φ28~Φ90) and mounting fittings.
Model designation is straightforward: EN – voltage / current — e.g. EN-24/250 is the 24kV / 250A bushing; reinforced-creepage versions carry the suffixes .01 / .02. Internal codes follow XD.current.voltage.EN. Voltage and current — two parameters fix the model.
The three groups: ① 1~3kV small-current (250~630A, three models); ② 1kV high-current (1000~3150A, four models with flat terminal pads); ③ 24~36kV MV (250A, three models, of which the two 36kV types are reinforced-creepage versions). The EN series is highly complementary to the DIN series — similar outlines at the same voltage steps with slightly different interface dimensions — allowing customers to match either standard system on the same transformer.
Table 1 | 1~3kV small-current group (250~630A)
| Code | Model | H | h2 | h3 | t | Md | d1 | d2 | S | S1 | Opening d0 | Creepage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XD.0250.1.EN | EN-1/250 | 167 | 30 | 3~6 | 5 | M12×1.75 | 53 | 11 | 22 | 15 | 28 | 55 |
| XD.0250.3.EN | EN-3/250 | 213 | 35.5 | 3~6 | 5 | M12×1.75 | 60 | 6.5 | 22 | 15 | 45 | 95 |
| XD.0630.1.EN | EN-1/630 | 235 | 30 | 3~6 | 9 | M20×2.5 | 70 | 12 | 32 | 14 | 45 | 70 |
Table 2 | 1kV high-current group (1000~3150A, flat terminal pads)
| Code | Model | H | h2 | h3 | t | Md | d1 | d2 | S | S1 | a2×a2 | a1×a1 | d4 | Opening d0 | Creepage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XD.1000.1.EN | EN-1/1000 | 268 | 39 | 3~6 | 12 | M30×2.0 | 90 | 2×Φ6.7 | 57 | 15 | 60×60 | 26×26 | 14 | 56 | 75 |
| XD.1250.1.EN | EN-1/1250 | 268 | 39 | 3~6 | 12 | M30×2.0 | 90 | 2×Φ6.7 | 57 | 15 | 60×60 | 26×26 | 14 | 56 | 75 |
| XD.2000.1.EN | EN-1/2000 | 314 | 45 | 6~10 | 15 | M42×3.0 | 104 | 2×Φ13 | 10 | 15 | 100×100 | 50×50 | 14 | 70 | 75 |
| XD.3150.1.EN | EN-1/3150 | 318 | 45 | 6~10 | 15 | M48×3.0 | 125 | 3×Φ13 | 10 | 15 | 120×120 | 60×60 | 14 | 90 | 75 |
※ Terminal pads: 2 holes for 1000~1250A, 2~3 holes from 2000A (column d2 = n×hole Ø); pad sizes a2×a2 / a1×a1; h3 is the thread-length range (printed 3"6 / 6"10 in the catalog, interpreted here as 3~6 mm / 6~10 mm).
Table 3 | 24~36kV MV group (250A; the 36kV types are the .01/.02 reinforced-creepage versions)
| Code | Model | H | h2 | h3 | h4 | Md | d1 | d2 | d3 | d4 | E | C | Opening d0 | Creepage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XD.0250.24.EN | EN-24/250 | 430 | 310 | 323 | 4 | M12×1.75 | 115 | 6.5 | 74 | 50 | 175 | 100 | 78 | 500 |
| XD.0250.33.EN.01 | EN-36/250 | 559 | 444 | 457 | 74 | M12×1.75 | 170 | 6.5 | 74 | 50 | 150 | 200 | 78 | 995 |
| XD.0250.33.EN.02 | EN-36/250 | 591 | 476 | 489 | 74 | M12×1.75 | 175 | 8 | 74 | 50 | 150 | 220 | 78 | 1116 |
※ MV group: uniform cover opening d0=78 with 4-M10 fixing holes (Φ58 PCD); E / C are the side offsets of the outdoor terminal. See the checklist for the h3 readings.
The LV group locates on cover openings of Φ28 / Φ45; the high-current group on Φ56 / Φ70 / Φ90, with terminal pads from 60×60 up to 120×120, hole patterns of 2×Φ6.7 to 3×Φ13, and threads rising from M30×2.0 to M48×3.0 with the current rating.
The MV group uses a uniform Φ78 opening (4-M10, Φ58 PCD). The two EN-36/250 versions .01 / .02 reinforce the creepage to 995 mm and 1116 mm respectively, suited to heavily polluted and humid areas.
| Application | Recommended Models | Notes |
|---|---|---|
| LV outlet of British-standard distribution transformers | EN-1/250 / EN-3/250 / EN-1/630 | Compact single-shed design, light weight, short arcing distance |
| High-current LV outlet (1~3.15kA) | EN-1/1000 ~ EN-1/3150 | Terminal pads up to 120×120, M48×3.0 thread |
| HV inlet of 24kV distribution transformers | EN-24/250 | Multi-shed brown porcelain, creepage 500 mm |
| 36kV heavily polluted / humid areas | EN-36/250 .01 / .02 | Creepage reinforced to 995 / 1116 mm |
| Mixed EN/DIN production lines | Full range | Interfaces complementary to the DIN series, sourced from one supplier |
The EN series is fully manufactured by Tianjin Xingda. Tooling for all 10 standard models is in place and supply is stable; listed dimensions refer to standard products, and non-standard sheds, extended heights and special openings can be customized to customer drawings. The same factory supplies EN, DIN, ANSI, NBR Brazilian and GB bushing lines, so a transformer manufacturer can equip both export and domestic units from a single purchase. Every bushing is delivered with sealing and mounting fittings, ready to assemble on the tank cover.
Contact: Tianjin Juyida Technology Co., Ltd
WhatsApp: +86 13662056855
Tel:
E-mail: solomon20210701@tjxddq.com
Add: Unit‑101, Workshop 3, Bozhong Automobile Industrial Park, No.5 Xianghui Road, Intersection of Xianghui Road and Gaoying Road, Beizhakou Town, Jinnan District, Tianjin, China